MIDI-FUSE FUSE 200A / 32V FOR 24V SYSTEM
Very easy programming
Load disconnection and reconnection time
Surge protection
Depending on your postal code
Delivered to you in 2/5 days
Warehouse - TEYRAN 34820
Description
The BatteryProtect protects the battery by disconnecting it from non-essential charges before it is completely discharged (which would damage it) or before it does not have enough power left to start the engine.
Very easy programming
BatteryProtect protection can be configured to activate / deactivate at different voltage levels. The 7-segment display will indicate which configuration has been chosen.
A special configuration for lithium-ion batteries
In this mode, the BatteryProtect can be controlled by the BMS of the VE-Bus.
Very low energy consumption
This is an important feature for lithium-ion batteries, especially after stopping at low voltage. Please see our technical sheet for lithium-ion batteries and the VE.Bus BMS manual for more information.
Surge protection
To avoid damaging the loads that are sensitive in the event of an overvoltage, the load is disconnected if the DC voltage exceeds 64 V.
Protection against combustion
No relay, but MOSFET transistors, and therefore there are no sparks.
Delayed alarm output
The alarm output is activated if the battery voltage drops for more than 12 seconds below the predetermined disconnection level. Starting the engine will therefore not activate the alarm. The alarm output is an open collector output protected against short circuits which is connected to the rail (negative), maximum current of 50 mA. The alarm output is generally used to activate a buzzer, an LED indicator or a relay.
Load disconnection and reconnection time
The load will be disconnected 90 seconds after the alarm is activated. If the battery voltage increases again to the connection threshold during this period (when the engine has been started for example), the load will not disconnect. The load will be connected again 30 seconds after the battery voltage has exceeded the preset charge reconnect voltage.
Data sheet
Shipping cost
Le frais de livraison sera automatiquement calculé en fonction de votre adresse de livraison une fois que vous aurez saisi votre code postal.
· Retrait en Magasin gratuit (Entrepôt - Teyran 34820)
· Retrait Lyon gratuit - Uniquement sur RDV( Vénissieux - 69200)
· Par DPD : les frais de livraison sont calculés par les poids de commande.
· Par transporteur DB SCHENKER : les frais de livraison sont calculés par les poids de commande et l’adresse de livraison.
verified reviews(5)
Philippe J. published the 19/10/2023 following an order made on 19/10/2023
Correspond à ce que j'attendais.
Anonymous A. published the 26/07/2021 following an order made on 26/07/2021
tres bien et rapide
Anonymous A. published the 31/05/2020 following an order made on 31/05/2020
sans commentaire
Anonymous A. published the 26/04/2020 following an order made on 26/04/2020
Pour le moment je n'ai pas reçu le bon modèle de fusible, mais celui que j'ai reçu fait son job. J'ai reçu des mega fuse à la place
Anonymous A. published the 15/04/2020 following an order made on 15/04/2020
Pas testé