MEGA-FUSE FUSE HOLDER - VICTRON ENERGY

Very easy programming

     Load disconnection and reconnection time

     Surge protection

€13.26 €15.60 -15%
VAT included

Description

The BatteryProtect protects the battery by disconnecting it from non-essential charges before it is completely discharged (which would damage it) or before it does not have enough power left to start the engine.

 

Very easy programming

BatteryProtect protection can be configured to activate / deactivate at different voltage levels. The 7-segment display will indicate which configuration has been chosen.

 

A special configuration for lithium-ion batteries

In this mode, the BatteryProtect can be controlled by the BMS of the VE-Bus.

 

Very low energy consumption

This is an important feature for lithium-ion batteries, especially after stopping at low voltage. Please see our technical sheet for lithium-ion batteries and the VE.Bus BMS manual for more information.

 

Surge protection

To avoid damaging the loads that are sensitive in the event of an overvoltage, the load is disconnected if the DC voltage exceeds 64 V.

 

Protection against combustion

No relay, but MOSFET transistors, and therefore there are no sparks.

 

Delayed alarm output

The alarm output is activated if the battery voltage drops for more than 12 seconds below the predetermined disconnection level. Starting the engine will therefore not activate the alarm. The alarm output is an open collector output protected against short circuits which is connected to the rail (negative), maximum current of 50 mA. The alarm output is generally used to activate a buzzer, an LED indicator or a relay.

 

Load disconnection and reconnection time

The load will be disconnected 90 seconds after the alarm is activated. If the battery voltage increases again to the connection threshold during this period (when the engine has been started for example), the load will not disconnect. The load will be connected again 30 seconds after the battery voltage has exceeded the preset charge reconnect voltage.

Data sheet

CIP000100001
1 kg

Shipping cost

Le frais de livraison sera automatiquement calculé en fonction de votre adresse de livraison une fois que vous aurez saisi votre code postal.

  

·        Retrait en Magasin gratuit (Entrepôt - Teyran 34820)

·        Retrait Lyon gratuit - Uniquement sur RDV( Vénissieux - 69200)

               

·        Par DPD : les frais de livraison sont calculés par les poids de commande.

·        Par transporteur DB SCHENKER : les frais de livraison sont calculés par les poids de commande et l’adresse de livraison.

   

verified reviews(32)

View the trust certificate
  • For further information on the nature of the review controls, as well as the possibility of contacting the author of the review please consult our CGU.
  • No inducements have been provided for these reviews
  • Reviews are published and kept for a period of five years
  • Reviews can not be modified: If a customer wishes to modify their review then they can do so by contacting Verified Reviews directly to remove the existing review and publish an amended one
  • The reasons for deletion of reviews are available here.

4.7 /5

Based on 32 customer reviews

  • 1
    1
  • 2
    0
  • 3
    2
  • 4
    3
  • 5
    26
Sort reviews by :

Eric H. published the 25/11/2023 following an order made on 31/10/2023

5/5

Conforme

Pierre M. published the 05/10/2023 following an order made on 12/09/2023

5/5

idem

Laurent J. published the 20/09/2023 following an order made on 27/08/2023

5/5

Bonne construction, c'est parfait....

Francis C. published the 12/08/2023 following an order made on 24/07/2023

4/5

conforme

Yannick S. published the 05/06/2023 following an order made on 29/04/2023

5/5

rapport qualité prix

Philippe L. published the 14/02/2023 following an order made on 31/01/2023

5/5

Très bien, conforme à mes attentes, je recommande !

Laurent B. published the 09/02/2023 following an order made on 28/01/2023

5/5

Pas encore mis en place,toute mon installation est à peine commencé je mettrais un com à la fin de mes travaux

FABIEN B. published the 18/01/2023 following an order made on 02/11/2022

4/5

Fait le boulot. Si on doit remplacer le fusible, il est solidaire des câbles, j'aurais bien vu de pouvoir changer le fusible en laissant les câbles en place pour éviter de les mettre en contact en cas de gros défaut

Roger S. published the 19/12/2022 following an order made on 07/10/2022

5/5

pas encore mis en place

Sandrine T. published the 14/11/2022 following an order made on 26/08/2022

3/5

difficile à évaluer pas encore mis en oeuvre

×

You might also like